HP
HPE FlexFabric 700760-B21 2 Port 10Gb PCIe 2.0 533FLR-T Adapter G9 G10
- SKU:
- 700760-B21
- UPC:
- 787322255607
- MPN:
- 700760-B21
- Condition:
- New
- Availability:
- Out of Stock
Description
HPE FlexFabric 700760-B21 Dual Port 10Gbps Ethernet PCI Express 2.0 x8 533FLR-T Network Adapter for ProLiant Gen9 Gen10 DL and Apollo Gen10 XL Servers (Brand New with 3 Years Warranty)
Accelerates Server Performance
The HPE FlexFabric 10Gb 2-port 533FLR-T Adapter boosts network performance with full line-rate 10GbE throughput across all ports.
Provides increased server performance by delivering full hardware offload for storage traffic.
Robust Virtualization Capabilities
The HPE FlexFabric 10Gb 2-port 533FLR-T Adapter delivers Single Root I/O Virtualization (SR-IOV) support to allow multiple operating systems to share a physical interconnect.
Supports VMware NetQueue and Microsoft VMQ technologies.
Enhances network management and efficiency with support for VLAN tagging.
Streamlines Deployment and Management
Makes QLogic Ethernet solutions available across a wide range of Hewlett Packard Enterprise server platforms.
Unifies NIC and storage management using HPE ProActive Insight architecture.
Provides backward compatibility with existing 1GbE networks and low-cost CAT 6a UTP cabling, supporting distances up to 100 meters.
The HPE FlexFabric 700760-B21 10 Gb 2-Port 533FLR-T Adapter increases throughput for the HPE ProLiant Gen9 and Gen10 DL and Apollo Gen9 and Gen10 XL Server series by using the innovative HPE FlexibleLOM form factor to offer dual-ports in a 10GBASE-T adapter configuration. This is an affordable choice for workload-intensive computing environments, providing a reliable, high performance 10GbE connectivity solution. The FlexFabric 533FLR-T offers everything you need plus the advanced features included in the FlexFabric series to simplifying your network and storage topology. This FlexFabric Dual Port 10GbE 533FLR-T Adapter comes with both Brackets (Full-Height and Half-Height Bracket) and comes with 3 Years Warranty.
Specification
Brand: HPE
MPN: 700760-B21
Option Part Number: 700760-B21
Spare Part Number: 701534-001
General
Device Type: Network Adapter - with Both Brackets (Full-Height and Half-Height Bracket)
Form Factor: FlexibleLOM (Plug-In Card)
Interface (Bus) Type: PCI Express 2.0 x8
PCI Specification Revision: PCIe 2.0
Networking
Cabling Type: Ethernet 10GBase-T
Connectivity Technology: Wired
Data Link Protocol: GigE, 10 GigE
Data Rate: 2 Port, each at 20 Gb Bidirectional, 40 Gb Bidirectional per Adapter
Data Transfer Rate: 10 Gbps
Ports: 10Gb Ethernet x 2
Status Indicators: Port Status, Link/Activity
Network Processor: Cavium 57810S
Jumbo Frames: 9000 KB
Standard Features: 802.1Q VLANs, Checksum & Segmentation Offload, Configuration Utilities, DPDK, HPE Sea Of Sensors 3D, IPv6, iSCSI/FCoE, Management Support, Jumbo Frames: 9000KB, Message Signaled Interrupt (Extended) (MSI-X), Network Adapter Teaming, Network Partitioning (NPAR), Optimized for Virtualization, LED Indicators, Preboot eXecution Environment (PXE), Receive Side Scaling (RSS), Server Integration, Single-Root I/O Virtualization, TCP/UDP/IP, TOE, Tunnel Offload, VMware NewQueue and Microsoft Virtual Machine Queue (VMQ)
IEEE Compliance: 802.3, 802.3ab, 802.3u, 802.3x, 802.3ad, 802.1q, 802.3az, 1588, 802.1as
Expansion & Connectivity
Interfaces: 2 x 10GBase-T - RJ-45
Processor / Memory
Processor: 1 x Cavium 57810S
RAM: 256 MB
Software / System Requirements
OS Required: SuSE Linux Enterprise Server 11 for x86/AMD64/Intel EM64T, SuSE Linux Enterprise Server 10 for x86/AMD64/Intel EM64T, Microsoft Windows Server 2008, Microsoft Windows HPC Server 2008, Microsoft Windows Small Business Server 2011 Standard, Microsoft Windows Small Business Server 2011 Essentials, Microsoft Windows MultiPoint Server 2011, Oracle Solaris 10, Red Hat Enterprise Linux 6.1, Red Hat Enterprise Linux 6.2, Red Hat Enterprise Linux 5.7, Citrix XenServer 6.0, Microsoft Windows Server 2012, Red Hat Enterprise Linux 5.8, Red Hat Enterprise Linux 5.9, Red Hat Enterprise Linux 6.3, Citrix XenServer 6.1, VMware vSphere 5.0, VMware vSphere 4.1
Power Requirement
Max Power Consumption: 18.20 Watt
Typical Power Consumption: 15.50 Watt
Miscellaneous
Compliant Standards: FCC Class A certified, UL, VCCI Class A ITE, EN55024, EN55022 Class A, ICES-003 Class A, WEEE, RoHS, BSMI Class A, EN 61000-3-2:2006, EN 61000-3-3:2008
Product Dimensions & Weight
Height: 2.25 inch
Width: 9.50 inch
Depth: 7.50 inch
Weight: 1.00 lbs
Environmental Parameters
Operating Temperature Range: 0° to 55°C (32° to 131°F)
Non-Operating Temperature Range: -65° to 85° C (-85° to 185° F)
Operating Humidity Range: 10% to 90% non-condensing
Non-Operating Humidity Range: 5% to 95% non-condensing
Compatibility Information
Designed for
HPE Apollo 4200 Gen9 Servers
HPE ProLiant DL Series: DL20 Gen9, DL360 Gen9, DL380 Gen9, DL120 Gen10, DL160 Gen10, DL180 Gen10, DL360 Gen10, DL380 Gen10, DL560 Gen10, DL580 Gen10, DL385 Gen10 Servers
HPE Apollo 2000 XL Series: XL170r Gen10, XL190r Gen10 Servers
HPE Apollo 4500 XL Series: XL450 Gen10 Servers
Standard Features
802.1Q VLANs
IEEE 802.1Q virtual local area network (VLAN) protocol allows each physical port of this adapter to be separated into multiple virtual NICs for added network segmentation and enhanced security and performance. VLANs increase security by isolating traffic between users. Limiting the broadcast traffic to within the same VLAN domain also improves performance.
Checksum & Segmentation Offload
Normally the TCP Checksum is computed by the protocol stack. Segmentation Offload is technique for increasing outbound throughput of high-bandwidth network connections by reducing CPU overhead. The technique is also called TCP segmentation offload (TSO) when applied to TCP, or generic segmentation offload (GSO).
Configuration Utilities
This adapter ships with a suite of operating system-tailored configuration utilities that allow the user to enable initial diagnostics and configure adapter teaming. This includes a patented teaming GUI for Microsoft Windows operating systems. Additionally, support for scripted installations of teams in a Microsoft Windows environment allow for unattended OS installations.
DPDK
This adapter supports DPDK with benefit for packet processing acceleration and use in NFV deployments.
HPE Sea of Sensors3D
Support for the HPE Sea of Sensors which is a collection of 32 sensors that automatically track thermal activity - heat - across the server. When temperatures get too high, sensors can initiate fans and make other adjustments to reduce energy usage. A significant improvement lies in the ability to apply fan speed increases only to the portion of the system that is rising in temperature, rather than all six fans in unison, which reduces the amount of energy used for cooling.
IPv6
IPv6 uses 128-bit addressing allowing for more devices and users on the internet. IPv4 supported 32-bit addressing.
Fibre Channel over Ethernet (FCoE)
Combines the functionality of an industry-standard NIC with an industry-proven Fibre Channel to seamlessly converge the traffic over a shared lossless Ethernet network.
Jumbo Frames
This adapter supports Jumbo Frames (also known as extended frames), permitting up to a 9,600 byte (KB) transmission unit (MTU) when running Ethernet I/O traffic. This is over five times the size of a standard 1500-byte Ethernet frame. With Jumbo Frames, networks can achieve higher throughput performance and greater CPU utilization. These attributes are particularly useful for database transfer and tape backup operations.
Message Signaled Interrupt (Extended)(MSI-X)
Message Signaled Interrupt (Extended) provides performance benefits for multi-core servers by load balancing interrupts between CPUs/cores.
Network Adapter Teaming
This adapter support for NIC teaming helps IT administrators increase network fault tolerance and increased network bandwidth, the team of adapters can work together as a single virtual adapter, providing support for several different types of teaming enabling IT administrators to optimize availability, improve performance and help reduce costs.
Network Partitioning (NPAR)
This adapter supports Network Partitioning (NPAR) allowing administrators to configure a 10 Gb port as four separate partitions or physical functions. Each PCI function is associated with a different virtual NIC. To the OS and the network, each physical function appears as a separate NIC port.
Optimized for Virtualization
I/O Virtualization support for VMware NetQueue and Microsoft VMQ helps meet the performance demands of consolidated virtual workloads.
LED Indicators
LED indicators show link integrity and network activity for easy troubleshooting.
Preboot eXecution Environment (PXE)
Support for PXE enables automatic deployment of computing resources remotely from anywhere. It allows a new or existing server to boot over the network and download software, including the operating system, from a management/ deployment server at another location on the network.
Additionally, PXE enables decentralized software distribution and remote troubleshooting and repairs.
Receive Side Scaling (RSS)
RSS resolves the single-processor bottleneck by allowing the receive side network load from a network adapter to be shared across multiple processors. RSS enables packet receive-processing to scale with the number of available processors.
Server Integration
This adapter is a validated, tested, and qualified solution that is optimized for HPE ProLiant servers. Hewlett Packard Enterprise validates a wide variety of major operating systems drivers with the full suite of web-based enterprise management utilities including HPE Intelligent Provisioning and HPE Systems Insight Manager that simplify network management. This approach provides a more robust and reliable networking solution than offerings from other vendors and provides users with a single point of contact for both their servers and their network adapters.
Single-Root I/O Virtualization
Single-Root I/O Virtualization (SR-IOV) provides a mechanism to bypass the host system hypervisor in virtual environments providing near metal performance and server efficiency. SR-IOV provides mechanism to create multiple Virtual Functions (VFs) to share single PCIe resources. The device is capable of SR-IOV, and requires Server BIOS support, controller firmware, and OS support.
TCP/UDP/IP
For overall improved system response, this adapter supports standard TCP/IP offloading techniques including: TCP/IP, UDP checksum offload (TCO) moves the TCP and IP checksum offloading from the CPU to the network adapter. Large send offload (LSO) or TCP segmentation offload (TSO) allows the TCP segmentation to be handled by the adapter rather than the CPU.
TOE
TCP/IP Offload Engine (TOE) shifts the processing of data in the TCP protocol stack from the server CPU to the adapter's processor, freeing server CPU cycles for other operations.
Tunnel Offload
Minimize the impact of overlay networking on host performance with tunnel offload support for VXLAN, NVGRE and GENEVE. By offloading packet processing to adapters, customers can use overlay networking to increase VM migration flexibility and virtualized overlay networks with minimal impact to performance. HPE Tunnel Offloading increases I/O throughput, reduces CPU utilization and lowers power consumption. Tunnel Offload supports VMware's VXLAN, Microsoft's NVGRE solutions and Generic Network Virtualization Encapsulation (GENEVE) solutions.
VMware NewQueue and Microsoft Virtual Machine Queue (VMQ)
VMware NetQueue is technology that significantly improves performance of 10 Gigabit Ethernet network adapters in virtualized environments. Windows Hyper-V VMQ (VMQ) is a feature available on servers running Windows Server 2008 R2 with VMQ-enabled Ethernet adapters. VMQ uses hardware packet filtering to deliver packet data from an external virtual machine network directly to virtual machines, which reduces the overhead of routing packets and copying them from the management operating system to the virtual machine.
Please contact with us if you have any question or to know the compatibility of this with your current server or storage array.